AGD 400 Semi Automatic Clinical Chemistry Analyser |
|
 |
|
| Technical Specifications: |
| |
| Assay Types |
End-point with Sample Blank and Bichromatic, Multi-Standard, Fixed Time, Kinetic, Coagulation and Immunoturbidimetry. |
| Wavelength |
Interference filter 340, 405, 450, 505, 546, 578, 620 nm and two free positions for optional filters. |
| Light Source |
6V/10W, Halogen Lamp. |
| Flow Cell |
32 μl flow cell with Peltier element. |
| Temperature Control |
25, 30, 32 and 37ºC with precision of ±0.1ºC. |
| Aspiration Volume |
From 0.5 ml to 1.0 ml in the steps of 0.1 ml for the flow cell. |
| Calibration |
Automatic, manual & one point calibration before each sample |
| Cuvette Mode |
Square cuvette of 10 mm path length to read 250µl.
Micro cuvette for coagulation. |
| Storage Capacity |
100 programs, 999 test records. |
| Screen Size |
240 x 128 dots. |
| Display |
Programs, processed data, curves for calibration and kinetic reactions, Levy-Jenning’s curve for Quality control data, Online Temperature, Absorbance and light transmitting capacity in terms of Frequency. |
| Printer |
Built-in Thermal Printer which can be switched ON/OFF, when desired. |
| Interface |
RS 232C |
| Power supply |
230 V AC±10V, 50 Hz |
| External Dimensions |
9”(L) x 17”(W) x 20”(H). |
| Weight |
5 Kg |
|
| |
| Salient Features: |
| |
 |
Used for in vitro biochemical investigations. |
|
|
 |
Near ultraviolet and visible programmable with user friendly software. |
|
|
 |
Built-in clock and calendar displayed online. |
|
|
 |
Built-in 'TIME OUT' device enables the instrument to enter into the STANDBY mode when the instrument is not in use. In this mode intensity of the photometer lamp is reduced and backlit of LCD is switched off. |
|
|
 |
Self check program for filters, lamp and printer before display of main menu. |
|
|
 |
6 digit 'PASSWORD' facility to program, modify or delete any procedure. |
|
|
 |
Zeroing, wavelength selection and temperature selection is automatic as per the chemistry programmed. |
|
|
 |
In end point and fixed time chemistries minimum 1 to maximum 10 calibrators can be used. 5 or more calibrators give a linearity curve which can be seen by a graphic display. |
|
|
 |
During run, online display of current temperature, absorbance, delay time, measuring time and frequency to check the performance of lamp and light transmitting capacity of the flow cell. |
|
|
 |
Kinetic reaction curves can be displayed, if desired. |
|
|
 |
15 absorbance readings during kinetic run can be printed, if required, irrespective of measuring time given in the program and calculates change in absorbance per minute and correlation of the reaction. |
|
|
 |
Facility to prevent the carryover of previous sample by rinsing the flow cell, if and when required. |
|
|
 |
Result can be printed automatically, manually and also from the memory at any time until the stored data is erased. |
|
|
 |
Plots Levy & Jennings graph to monitor and provide statistics for quality control results. |
|
|
 |
All results of the patient with particular identification number aretransferred to DATA PRINT in Utilities menu and can be displayed and printed out patient wise, if and when desired. |
|
|
|